WATER TESTING INSTRUMENTS
Turbidity Meters
Turbidity can be calculated in the laboratory using a bench turbidity meter, in outdoor and field applications a portable turbidity meter would be used and for plant and process applications a permanent online controller would be used. Turbidity meters use an instrument called a nephelometer with the detector system to the side of the light beam. More light reaches the detector if there are lots of small particles reflecting the source beam than if there are few. The units of turbidity from a calibrated nephelometer are called Nephelometric Turbidity Units (NTU).
CL-880
RANGE
0-1NTU, 0-10 NTU 0-100 NTU, 0-1000 NTU ±3% OF F.S. IN 0 1 & 0- 1000NTU RANGE (UP TO 500)
ACCURACY
{DUE TO NATURE OF SAMPLES READINGS MAY NOT BE LINER ABOVE 500}, ± 2% OF F.S. IN 0- 10 & 0-100 NTU RANGE
REPRODUCIBILITY
WITH IN ± 3% OF F.S.
DETECTOR
PHOTO-CELL
WORK ON 220 V AC
Dissolve Oxygen Meters
A dissolved oxygen meter is used to calculate the quantity of oxygen there in a unit volume of water. Now the next subject that arises is, why do I need to calculate the amount of oxygen in water? This is because it indicates if the water is useful for a specific application like water treatment plants, sewage treatment works, river monitoring and fish farming.
CL-930
Display
2 ½ Digit LCD
D.O. Range
0 to 20 PPM
Temp. Accuracy
-5 to 45°
D.O.
± 1 % of Full Scale
Temp. Resolution
± 1°C
D.O.
0.1 PPM
Temp.
0.1°C
WORK ON 220 V AC
Spectrophotometers
Spectrophotometry involves the use of a spectrophotometer. A spectrophotometer is a photometer (a apparatus for measuring light intensity) that can calculate strength as a function of the light source wavelength. Important features of spectrophotometers are spectral bandwidth and linear range of absorption or reflectance measurement.
CL-330
WAVE LENGTH
RANGE
340 TO 990NM
ACCURACY
± 1 NM
READ OUT
3½ DIGIT LED, 1 NM STEP
BANDWIDTH
5.0 NM
PHOTOMETRIC
RANGE
0.3 TO 2.500 ABS
GRATING
600 LINES / MM
SOURCE
TUNGSTEN HALOGEN LAMP 12 V, 50 W
DETECTOR
SILICON PHOTO DIODE
MEASURING MODE
% T, ABS,CONC
K FACTOR RANGE
0.0 TO 9999
CONC. RANGE
0 TO 9999
WORK ON 220 V AC
Digital Melting Point Apparatus
Digital Automatic Melting Point Apparatus is planned for quick and perfect detection of melting point. Feature packed & easy to use. This is an necessary bench top tool. This equipment has an arrangement to hold the capillary containing the sample in uniformly heating media. The hotness is indicated on a digital display readable in 1.0° C. At the point, when the sample melts, the heating is automatically cut-off and the digital display showing the temperature remains on the indicator till it is cleared.
CL-726
Temperature Range
Room Temp to 300° C
Readability
0.1° C
Accuracy
± 0.5 %
AUTO RELAY CUT OFF FOR MELTING POINT AND BOILING POINT
WORK ON 220 V AC.
Photo Florimeter
CL 950
SENSITIVITY
F.S. DEFLECTION WITH 0.1 PPM QUININE SULPHETE
IN 0.1 N SULFURIC ACID SOLUTION ( {PRIMARY
W/L 360 NM)
DISPLAY
3 DIGIT
SAMPLE TEST TUBE
15MM * 80MM
MIN. SAMPLE
4ML
SOURCE
12 V, 50HZ LAMP
FILTERS
PRIMARY
360 NM, 440NM
SECONDARY
485 NM, 640NM AND
ABOVE, 550NM AND ABOVE
DETECTOR
PHOTO CELL
WORK ON 220 V AC.
Auto Karl Fisher Titrate
CL -510
MIN. DETECTABILITY
0.5 MG. OF MOISTURE
ACCURACY
0.25 MG
BURETTE CAPACITY
10ML
BURETTE RESOLUTION
0.05 ML
STIRRER
VARIABLE SPEED
END POINT
ELECTRONICALLY TIMED WITH AUDIBLE BUZZER AND A BAR LED DISPLAY